logo
Mengirim pesan
Harga yang bagus  on line

rincian produk

Rumah > Produk >
Kabinet Telekomunikasi Luar Ruang
>
Kabinet Distribusi Daya Pole Mount Dengan Baterai UPS Dan Unit Monitoring

Kabinet Distribusi Daya Pole Mount Dengan Baterai UPS Dan Unit Monitoring

Nama merek: daxin
Nomor Model: Daxin-7058350
MOQ: 1pcs
Rincian kemasan: Kotak kayu/ kertas
Ketentuan Pembayaran: T/T, MoneyGram, Western Union
Informasi Rinci
Place of Origin:
SHENZHEN
Sertifikasi:
CE
Features:
Power distribution/ Battery back up. monitory
Product name:
Outdoor Telecom Cabinet
Design:
Custom design based on client's requirments
Cara gunung:
Pemasangan Tiang
Power distribution:
yes
Cabinet Lock:
Round lock
Monitory:
Yes
Dimension:
700mm*580mm*350mm
Supply Ability:
10000pcs/month
Menyoroti:

Kabinet Distribusi Daya Baterai UPS

,

Unit pemantauan Kabinet distribusi listrik

,

Kabinet Distribusi Daya Pole Mount

Deskripsi Produk

 

Kabinet Distribusi Daya Pole Mount Dengan Baterai UPS Dan Unit Monitor 


Rincian singkat:

 

Sistem daya yang dipasang di dinding dalam ruangan dan di luar ruangan seri UPS terdiri dari satu modul daya UPS khusus komunikasi seri E atau satu modul daya inverter khusus komunikasi seri N,dengan daya keluar 500VA ~ 3000VA opsionalSistem ini dapat dipasang di dinding di dalam atau di luar ruangan, dan membentuk sistem pasokan listrik tanpa gangguan dengan baterai.

 

 

■ Dengan fungsi operasi tanpa awak, lebih cocok untuk tempat dengan sedikit penjaga seperti stasiun pangkalan dan puncak gunung

Dilengkapi dengan sistem pengisian dan manajemen arus tinggi, dapat beradaptasi untuk mengelola baterai lithium iron phosphate atau baterai asam timbal biasa

Mengadopsi sepenuhnya teknologi kontrol digital DSP, produk lebih stabil dan kualitasnya lebih tinggi

■ Kisaran kerja tegangan input AC: 172-268Vac

Mengadopsi koreksi faktor daya aktif, faktor daya dapat mencapai hingga 0.98

Perlindungan atas dan di bawah tegangan input DC

Faktor daya beban adalah 0.8, dengan kapasitas beban yang lebih besar

Sistem beroperasi dalam kisaran suhu yang luas dari -15 °C sampai +55 °C

■ rentang frekuensi tegangan masukan yang luas, mampu bekerja secara normal bahkan di daerah terpencil dengan lingkungan daya yang sangat keras, mengurangi waktu debit baterai dan meningkatkan umur baterai

Mode kerja online transformasi ganda, nol beralih, secara efektif memastikan keamanan dan keandalan operasi beban

■ Fungsi pemantauan jarak jauh yang komprehensif, menyediakan antarmuka RS232 standar, antarmuka RS485 dan kartu pemantauan jaringan opsional, kontak kering juga dapat dipilih,

Tingkat perlindungan: IP54 untuk penggunaan di luar ruangan dan IP20 untuk penggunaan di dalam ruangan

 

 

Parameter teknis dari lemari telekomunikasi luar:

 

 

Model AAM500-12V AAM500-24V AAM1K-24V AAM1K-48V AAM2K-48V AAM3K-48V
Kapasitas pelat nama 500VA/400W 1KVA/800W 2KVA/1,6KW 3KVA/2,4KW
Masukan AC Tegangan nominal 220VAC, input harmonik 3%
Masukan DC Rating 12V Rating 24V Rating 24V Rating 48V Rating 48V Rating 48V
Output AC Output Inverter AC 220V;
Transitor tegangan dinamis: 5%;
Waktu pemulihan sementara dinamis: 60 ms;
THD:3% ((Linear load);THD:8% ((Nonlinear load);
Kapasitas overload: 130% terus-menerus tidak kurang dari 20 detik;
Koefisien puncak arus keluar:31:1;
Waktu beralih DC dan AC:0ms;
Invert to bypass switch time: 4ms
Listrik pengisian 5-7A
Fungsi perlindungan Perlindungan atas tegangan input DC, perlindungan atas tegangan bawah, perlindungan atas tegangan output, perlindungan atas beban, perlindungan atas suhu, perlindungan terhadap sirkuit pendek
Mode Operasi Operasi depan kabel depan Operasi depan diikuti dengan kabel

 

Parameter Lingkungan Kabinet

Parameter Lingkungan Kondisi lingkungan untuk penggunaan Kondisi lingkungan transportasi Kondisi lingkungan penyimpanan sesuai dengan Catatan
jenis parameter unit Standar yang relevan
Cuaca suhu eksternal suhu rendah °C - 40 - 40 -25 YD/T1058-2000 中 "-40 ° C dapat memulai dengan beban penuh,
suhu tinggi °C 45 70 55 4.1.1 dan 4.1.2 "+55~+65°CLinear derating20%.
perubahan suhu °C/menit / 1 / ETS300019-2-2T2.3  
kelembaban kelembaban relatif % 5-90 90 ((40±2°C) / YD/T1058-2000 中4.1.3 Persyaratan pengujian jangka pendek: 0-95%, nilai maksimum 95%, non-kondensasi
  Tekanan udara Tekanan rendah Kpa 86 70 70 YD/T1058-2000 中4.1.4 Hanya berlaku untuk modul
  tekanan atmosfer tinggi Kpa 106 106 106  
ketinggian m ≤ 4000 Ketika ketinggian melebihi 2000m, untuk setiap peningkatan 100m suhu menurun sebesar 0,5 °C
  

Karakteristik listrik

 

1 Karakteristik input
 
Nomor Seri proyek persyaratan teknis unit Catatan
1.1 Tegangan Masuk 90 ¢ 300 VAC 176-300Vac output beban penuh, 90-175Vac output beban berkurang
1.2 arus maksimum masukan 57 A  
1.3 Tegangan Nominal Masuk 220 VAC Tegangan fase
1.4 Frekuensi tegangan masuk 47 ¢ 63 (nilai khas adalah 50/60) Hz  
1.5 Faktor daya masukan ≥ 0.99   Keadaan kerja beban penuh
 
 
2 karakteristik output
 
Nomor Seri proyek persyaratan teknis Satuan Catatan
2.1 Tegangan output nominal - 54 Vdc IN220Vac
2.2 Jangkauan tegangan output -42 ¢ -58 Vdc Diatur melalui pemantauan (kondisi uji: tidak ada beban)
2.3 Listrik output nominal 150 A  
2.4 Kekuatan nominal output 8.7 KW  
2.5 Gelombang output dan kebisingan ≤ 200 mVp-p Lebar band osiloskop harus 20MHz,
Probe sejajar dengan kondensator 10u+104
2.6 Penundaan output startup 3 ¢ 8 S IN 220Vac,
2.7 Keakuratan stabilisasi tegangan ≤ ± 1%    
2.8 Indeks kebisingan Gangguan broadband ≤ 100 mV 3.4 ¢ 150 KHz
Tegangan suara ≤ 30 mV 150-30 MHz
Berat saldo telepon ≤ 2 mV  
tegangan suara
2.9 dinamika Amplitudo overshoot △V:≤5 % Vo 25% 50% 25%
sebagai tanggapan atas waktu pemulihan △t: ≤ 500 μS Perubahan beban 50% ∼75% ∼50%
2.1 Distribusi arus yang tidak merata ≤ 5%   Modul paralel 50% -100% output nominal
(Modul fungsional dapat bekerja secara paralel)
2.11 Koefisien suhu ± 0.02 %/°C  
2.12 efisiensi output ≥ 95%   220Vac/T beban nominal (nilai khas), modul efisiensi tinggi
≥92%   220Vac/T beban nominal (nilai khas), modul universal
≥ 87%   110VAC/beban nominal
  

 
Produk gambar nyata dan pabrik kami:

 

 

Kabinet Distribusi Daya Pole Mount Dengan Baterai UPS Dan Unit Monitoring 0Kabinet Distribusi Daya Pole Mount Dengan Baterai UPS Dan Unit Monitoring 1
 
Kabinet Distribusi Daya Pole Mount Dengan Baterai UPS Dan Unit Monitoring 2Kabinet Distribusi Daya Pole Mount Dengan Baterai UPS Dan Unit Monitoring 3Kabinet Distribusi Daya Pole Mount Dengan Baterai UPS Dan Unit Monitoring 4
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
Harga yang bagus  on line

rincian produk

Rumah > Produk >
Kabinet Telekomunikasi Luar Ruang
>
Kabinet Distribusi Daya Pole Mount Dengan Baterai UPS Dan Unit Monitoring

Kabinet Distribusi Daya Pole Mount Dengan Baterai UPS Dan Unit Monitoring

Nama merek: daxin
Nomor Model: Daxin-7058350
MOQ: 1pcs
Rincian kemasan: Kotak kayu/ kertas
Ketentuan Pembayaran: T/T, MoneyGram, Western Union
Informasi Rinci
Place of Origin:
SHENZHEN
Nama merek:
daxin
Sertifikasi:
CE
Nomor model:
Daxin-7058350
Features:
Power distribution/ Battery back up. monitory
Product name:
Outdoor Telecom Cabinet
Design:
Custom design based on client's requirments
Cara gunung:
Pemasangan Tiang
Power distribution:
yes
Cabinet Lock:
Round lock
Monitory:
Yes
Dimension:
700mm*580mm*350mm
Minimum Order Quantity:
1pcs
Kemasan rincian:
Kotak kayu/ kertas
Delivery Time:
15-25 days
Payment Terms:
T/T, MoneyGram, Western Union
Supply Ability:
10000pcs/month
Menyoroti:

Kabinet Distribusi Daya Baterai UPS

,

Unit pemantauan Kabinet distribusi listrik

,

Kabinet Distribusi Daya Pole Mount

Deskripsi Produk

 

Kabinet Distribusi Daya Pole Mount Dengan Baterai UPS Dan Unit Monitor 


Rincian singkat:

 

Sistem daya yang dipasang di dinding dalam ruangan dan di luar ruangan seri UPS terdiri dari satu modul daya UPS khusus komunikasi seri E atau satu modul daya inverter khusus komunikasi seri N,dengan daya keluar 500VA ~ 3000VA opsionalSistem ini dapat dipasang di dinding di dalam atau di luar ruangan, dan membentuk sistem pasokan listrik tanpa gangguan dengan baterai.

 

 

■ Dengan fungsi operasi tanpa awak, lebih cocok untuk tempat dengan sedikit penjaga seperti stasiun pangkalan dan puncak gunung

Dilengkapi dengan sistem pengisian dan manajemen arus tinggi, dapat beradaptasi untuk mengelola baterai lithium iron phosphate atau baterai asam timbal biasa

Mengadopsi sepenuhnya teknologi kontrol digital DSP, produk lebih stabil dan kualitasnya lebih tinggi

■ Kisaran kerja tegangan input AC: 172-268Vac

Mengadopsi koreksi faktor daya aktif, faktor daya dapat mencapai hingga 0.98

Perlindungan atas dan di bawah tegangan input DC

Faktor daya beban adalah 0.8, dengan kapasitas beban yang lebih besar

Sistem beroperasi dalam kisaran suhu yang luas dari -15 °C sampai +55 °C

■ rentang frekuensi tegangan masukan yang luas, mampu bekerja secara normal bahkan di daerah terpencil dengan lingkungan daya yang sangat keras, mengurangi waktu debit baterai dan meningkatkan umur baterai

Mode kerja online transformasi ganda, nol beralih, secara efektif memastikan keamanan dan keandalan operasi beban

■ Fungsi pemantauan jarak jauh yang komprehensif, menyediakan antarmuka RS232 standar, antarmuka RS485 dan kartu pemantauan jaringan opsional, kontak kering juga dapat dipilih,

Tingkat perlindungan: IP54 untuk penggunaan di luar ruangan dan IP20 untuk penggunaan di dalam ruangan

 

 

Parameter teknis dari lemari telekomunikasi luar:

 

 

Model AAM500-12V AAM500-24V AAM1K-24V AAM1K-48V AAM2K-48V AAM3K-48V
Kapasitas pelat nama 500VA/400W 1KVA/800W 2KVA/1,6KW 3KVA/2,4KW
Masukan AC Tegangan nominal 220VAC, input harmonik 3%
Masukan DC Rating 12V Rating 24V Rating 24V Rating 48V Rating 48V Rating 48V
Output AC Output Inverter AC 220V;
Transitor tegangan dinamis: 5%;
Waktu pemulihan sementara dinamis: 60 ms;
THD:3% ((Linear load);THD:8% ((Nonlinear load);
Kapasitas overload: 130% terus-menerus tidak kurang dari 20 detik;
Koefisien puncak arus keluar:31:1;
Waktu beralih DC dan AC:0ms;
Invert to bypass switch time: 4ms
Listrik pengisian 5-7A
Fungsi perlindungan Perlindungan atas tegangan input DC, perlindungan atas tegangan bawah, perlindungan atas tegangan output, perlindungan atas beban, perlindungan atas suhu, perlindungan terhadap sirkuit pendek
Mode Operasi Operasi depan kabel depan Operasi depan diikuti dengan kabel

 

Parameter Lingkungan Kabinet

Parameter Lingkungan Kondisi lingkungan untuk penggunaan Kondisi lingkungan transportasi Kondisi lingkungan penyimpanan sesuai dengan Catatan
jenis parameter unit Standar yang relevan
Cuaca suhu eksternal suhu rendah °C - 40 - 40 -25 YD/T1058-2000 中 "-40 ° C dapat memulai dengan beban penuh,
suhu tinggi °C 45 70 55 4.1.1 dan 4.1.2 "+55~+65°CLinear derating20%.
perubahan suhu °C/menit / 1 / ETS300019-2-2T2.3  
kelembaban kelembaban relatif % 5-90 90 ((40±2°C) / YD/T1058-2000 中4.1.3 Persyaratan pengujian jangka pendek: 0-95%, nilai maksimum 95%, non-kondensasi
  Tekanan udara Tekanan rendah Kpa 86 70 70 YD/T1058-2000 中4.1.4 Hanya berlaku untuk modul
  tekanan atmosfer tinggi Kpa 106 106 106  
ketinggian m ≤ 4000 Ketika ketinggian melebihi 2000m, untuk setiap peningkatan 100m suhu menurun sebesar 0,5 °C
  

Karakteristik listrik

 

1 Karakteristik input
 
Nomor Seri proyek persyaratan teknis unit Catatan
1.1 Tegangan Masuk 90 ¢ 300 VAC 176-300Vac output beban penuh, 90-175Vac output beban berkurang
1.2 arus maksimum masukan 57 A  
1.3 Tegangan Nominal Masuk 220 VAC Tegangan fase
1.4 Frekuensi tegangan masuk 47 ¢ 63 (nilai khas adalah 50/60) Hz  
1.5 Faktor daya masukan ≥ 0.99   Keadaan kerja beban penuh
 
 
2 karakteristik output
 
Nomor Seri proyek persyaratan teknis Satuan Catatan
2.1 Tegangan output nominal - 54 Vdc IN220Vac
2.2 Jangkauan tegangan output -42 ¢ -58 Vdc Diatur melalui pemantauan (kondisi uji: tidak ada beban)
2.3 Listrik output nominal 150 A  
2.4 Kekuatan nominal output 8.7 KW  
2.5 Gelombang output dan kebisingan ≤ 200 mVp-p Lebar band osiloskop harus 20MHz,
Probe sejajar dengan kondensator 10u+104
2.6 Penundaan output startup 3 ¢ 8 S IN 220Vac,
2.7 Keakuratan stabilisasi tegangan ≤ ± 1%    
2.8 Indeks kebisingan Gangguan broadband ≤ 100 mV 3.4 ¢ 150 KHz
Tegangan suara ≤ 30 mV 150-30 MHz
Berat saldo telepon ≤ 2 mV  
tegangan suara
2.9 dinamika Amplitudo overshoot △V:≤5 % Vo 25% 50% 25%
sebagai tanggapan atas waktu pemulihan △t: ≤ 500 μS Perubahan beban 50% ∼75% ∼50%
2.1 Distribusi arus yang tidak merata ≤ 5%   Modul paralel 50% -100% output nominal
(Modul fungsional dapat bekerja secara paralel)
2.11 Koefisien suhu ± 0.02 %/°C  
2.12 efisiensi output ≥ 95%   220Vac/T beban nominal (nilai khas), modul efisiensi tinggi
≥92%   220Vac/T beban nominal (nilai khas), modul universal
≥ 87%   110VAC/beban nominal
  

 
Produk gambar nyata dan pabrik kami:

 

 

Kabinet Distribusi Daya Pole Mount Dengan Baterai UPS Dan Unit Monitoring 0Kabinet Distribusi Daya Pole Mount Dengan Baterai UPS Dan Unit Monitoring 1
 
Kabinet Distribusi Daya Pole Mount Dengan Baterai UPS Dan Unit Monitoring 2Kabinet Distribusi Daya Pole Mount Dengan Baterai UPS Dan Unit Monitoring 3Kabinet Distribusi Daya Pole Mount Dengan Baterai UPS Dan Unit Monitoring 4